Suitable is the best. High and Low Environmental Test Chambers .
MGDW Series - High and Low Temperature Chambers (Standard)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Humidity)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions:  Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions:  Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
MGDW Series - High and Low Temperature Chambers (Double layer standard)
					 Volume: 150L/225L; 
Test Method: GB/T 5170.2-2017; 
Temperature Range: 20℃~150℃; -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)
					 Volume: 150L/225L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)
					 Volume: 150L/225L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
Suitable is the best. High Environmental Test Chambers .
High Temperature Test Chambers (Standard)
					Test Method: GB/T 5170.2-2017;
Volume: 100L/150L/225L/408L/800L/1000L;
Temperature Range: (Environmental Temperature +15℃)~150℃;
Temperature Fluctuation:≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: (Environmental Temperature +15℃)→+150℃ ≤ 40 min;
				
High Temperature Test Chambers (Explosion proof)
					Test Method: GB/T 5170.2-2017;
Volume: 100L/150L/225L/408L/800L/1000L;
Temperature Range: (Environmental Temperature +15℃)~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: (Environmental Temperature +15℃)→+150℃ ≤ 40 min;
				
High Temperature Test Chambers (Automatic fire extinguishing & Explosion proof)
					Test Method: GB/T 5170.2-2017;
Volume: 100L/150L/225L/408L/800L/1000L;
Temperature Range: (Environmental Temperature +15℃)~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: (Environmental Temperature +15℃)→+150℃ ≤ 40 min;
				
Suitable is the best. Environmental Test Chambers .
25L constant integrated temperature test chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
200L constant integrated temperature test chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
300L constant integrated temperature test chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
500L constant integrated temperature test chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
25L Constant Temperature Split Test Chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: -20℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-20℃≤45min (No load, average nonlinearity);
				
480L Constant Temperature Split Test Chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
480L Constant Temperature Split Test Chambers(Export Version)
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~85℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→85℃≤40min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50min (No load, average nonlinearity);
				
Dual Temperature Zone Constant Temperature Integrated Chambers
					Test Method: GB/T 5170.2-2017;
Temperature Range: 0~60℃;
Temperature Fluctuation: ≤1℃ (Equivalent to ±0.5℃, under no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: 25℃→60℃≤30min (No load, average nonlinearity);
Cooling Time: 25℃→0℃≤50 min (No load, average nonlinearity);
				
Suitable is the best. Explosion proof Test Chambers .
Dual Explosion-proof Test Chambers (350L)
					Nominal Internal Volume: 350L;
Inside Dimensions:W780 mm×D680 mm×H330 mm(单库位);
Overall Dimensions: W950 mm×D980 mm×H1400 mm;
Net Weight: About 240kg;
Environmental Conditions: Temperature:5℃~35℃; Relative Humidity:≤85%; Atmospheric Pressure:86kPa~106kPa;
				
20 Storage Location Explosion-proof Test Chambers (220L)
					Nominal Internal Volume: 220L;
Inside Dimensions:W180 mm×D350 mm×H180 mm(单库位);
Overall Dimensions: W950 mm×D910 mm×H1600 mm (Without Protrusions);
Net Weight: About 300kg;
Environmental Conditions: Temperature:5℃~35℃; Relative Humidity:≤85%; Atmospheric Pressure:86kPa~106kPa;
				
 
 
	 
  
  
  
  
 
           
  
  
  
  
    
  
                     
  
                     
  
  
  
 
	 
  
  
  
  
  
  
  
  
  
  
  
  언어
언어 