				 Temperature Deviation±2.0℃ Temperature Deviation±2.0℃
 (When no load and temperature is stable)
- 
				 Test Ambient Temperature+25℃ Test Ambient Temperature+25℃
- 
				 Temperature Range-20℃~150℃ Temperature Range-20℃~150℃
- 
				 Cooling Time≤45 min Cooling Time≤45 min
 (+20℃→-20℃)
- 
				 Heating Time≤60 min Heating Time≤60 min
 (-20℃→+150℃)
- 
				 Temperature Fluctuation≤1℃ Temperature Fluctuation≤1℃
 (When no load and temperature is stable)
| Typical Model | ||||
| MGDW-150-20H | MGDW-150-40H | MGDW-225-20H | MGDW-225-40H | MGDW-225-70H | 
| MGDW-408-20H | MGDW-408-40H | MGDW-408-70H | MGDW-800-20H | MGDW-800-40H | 
| MGDW-800-70H | MGDW-1000-20H | MGDW-1000-40H | MGDW-1000-70H | 
 
 
Suitable is the best. High and Low Environmental Test Chambers .
WGDW SERIES High-Low Environmental Test Chambers (Coin cell All-in-one)
					Volume: 150L/225L;
Material coding: WGDW-225L-40-mA160CH;
Test Method:  GB/T 5170.2-2017; 
Temperature Range: -40℃~85℃;
Temperature Fluctuation: ≤1℃ (no load and stable temperature);
Temperature Deviation: ±1.5℃ (no load and stable temperature);
Heating Up Time: +20℃→+85℃ ≤40 min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);
				
WGDW SERIES High-Low Environmental Test Chambers (3C All-in-one)
					Volume: 50L;
Material coding: WGDW-50L-40-5V30A16CH;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~100℃;
Temperature Fluctuation: ≤±0.5℃(no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→+100℃ ≤40 min(No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Standard)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Humidity)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions:  Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)
					 Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃; 
-40℃~+150℃; 
-70℃~+150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions:  Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
MGDW Series - High and Low Temperature Chambers (Double layer standard)
					 Volume: 150L/225L; 
Test Method: GB/T 5170.2-2017; 
Temperature Range: 20℃~150℃; -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
				
MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)
					 Volume: 150L/225L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
				
MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)
					 Volume: 150L/225L;
Test Method: GB/T 5170.2-2017; 
Temperature Range: -40℃~150℃; 
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature); 
Temperature Deviation: ±2.0℃ (no load and stable temperature); 
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity); 
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity); 
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
				
 
  
  
  
  
 
           
  
  
  
 
 
  
  
  
  
  
  
  
  
  
  
  